Circuit Load Calculator
What needs power?
Count the everyday stuff first — outlets and lights.
Rule of thumb: up to 10 outlets per 15A circuit, 12 fixtures per lighting circuit.
Kitchen, baths & big stuff
These get dedicated circuits — code says so.
Your circuit plan
You need
–
- General 15A
- –
- Kitchen 20A
- –
- Bath 20A
- –
- Lighting 15A
- –
- 240V circuits
- –
- Est. wire
- –
💡 Pro field tips
🧰 Tools you'll need
Tap to check off as you load up.
Est. project cost (optional)
File this estimate under a job name or PO to track what to order. Leave blank to file under "General".
Copied to clipboard ✓
Size a breaker for one load
Know the watts of one appliance or tool? Get its amps and a planning breaker size.
Planning figure only — confirm the final breaker and wire size against NEC ampacity tables and local code with a licensed electrician before installing.
How the math works
This calculator does not size breakers from watts in the planner — it counts how many circuits a job needs, the way an electrician lays out a panel before any wire is pulled. You count the outlets, fixtures, bathrooms and big appliances; the tool turns those counts into circuits, panel spaces, and a cable estimate. For one single load, the breaker sizer under the planner (just above this section) works from watts instead.
Step 1: General outlets — 1 circuit per 10
General circuits = your outlet count ÷ 10, rounded up. 25 outlets ÷ 10 = 2.5, so 3 general 15A circuits.
Step 2: Kitchens get 2 dedicated circuits
If the job has any kitchen counter outlets, the count adds 2 dedicated 20A circuits — the code minimum for countertop appliances. No kitchen outlets, no added circuits.
Step 3: One circuit per bathroom
Each bathroom adds 1 dedicated 20A circuit.
Step 4: Lighting — 1 circuit per 12 fixtures
Lighting circuits = fixtures ÷ 12, rounded up, at 15A. 24 fixtures ÷ 12 = exactly 2 lighting circuits.
Step 5: 240V appliances take 2 panel spaces
Each 240V appliance (range, dryer, water heater) counts as 1 circuit but 2 spaces in the panel, because its breaker is a double-pole breaker.
Step 6: Cable estimate
The tool figures about 40 ft of cable per circuit, and rounds up to full 250-ft rolls.
Step 7: Sizing a breaker for one load
The breaker sizer under the planner works from a single load. The formula is Amps = Watts ÷ Volts: a 1,500-watt space heater on 120 volts draws 1,500 ÷ 120 = 12.5 amps. If the load runs 3+ hours at a time — a continuous load, like a space heater or an EV charger — code figures it at 125%: 12.5 × 1.25 = 15.63 amps. Then take the next standard breaker size up: 20A. Standard sizes run 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100. And the breaker protects the wire, so the wire must match the breaker — 14-gauge copper minimum on a 15A breaker, 12-gauge on a 20A.
Worked example
25 outlets, 24 light fixtures, kitchen counter outlets, 2 bathrooms, 1 dryer (240V): general 3 + kitchen 2 + bath 2 + lighting 2 + 240V 1 = 10 circuits, taking 11 panel spaces, with about 400 ft of cable (2 rolls).
Planning estimates only — breaker sizing, panel capacity and all electrical work must follow the NEC and local rules; when in doubt, hire a licensed electrician.
Most Asked Questions
How many general circuits do I need for 25 outlets?
3 general circuits. The calculator allows 10 general outlets per 15A circuit and rounds up: 25 ÷ 10 = 2.5, so 3 circuits. It is a planning count — size for the realistic worst case on each circuit, not the typical Tuesday.
How many kitchen circuits does the calculator plan?
2 dedicated 20A circuits, as soon as any counter outlets are entered. Kitchen counter outlets trigger the code-minimum pair of dedicated small-appliance circuits. Enter no counter outlets and the kitchen count is 0 — the two circuits exist because counters are where the heavy small appliances gather.
How many circuits does each bathroom get?
1 dedicated 20A circuit per bathroom. Enter 2 bathrooms and the plan adds 2 bathroom circuits. Bathrooms get their own dedicated circuits — code, not opinion — because hair dryers and heaters are big loads in a wet room.
How are lighting circuits counted?
1 circuit for every 12 light fixtures, rounded up. 25 fixtures ÷ 12 = 2.08, so the plan calls for 3 lighting circuits. Like the outlet count, it is an exact planning count from the numbers you enter — no hidden extra circuits are added.
How much panel space does a 240V appliance take?
2 panel spaces for each 240V appliance — while counting as 1 circuit. A dryer or range breaker is a double-pole breaker, so it eats two slots. The results keep the two numbers separate: total circuits for the plan, and total panel spaces so you can see whether the panel itself is big enough — over 40 spaces, the calculator flags that you may need a subpanel.
How much cable does the calculator estimate?
About 40 ft of cable per circuit, rolled up into 250-ft rolls. A 5-circuit plan figures roughly 200 ft of cable, which is 1 roll. It is a rough-in planning estimate — real runs depend on where the panel sits and how the walls route, so measure your actual paths before you buy.
How do I size a breaker for one appliance?
Use the breaker sizer under the planner: amps = watts ÷ volts. A 1,500 W space heater on 120 V draws 12.5 A. Because it runs for hours, it counts as a continuous load — multiply by 1.25 (15.63 A) and take the next standard size up: a 20A breaker. It is a planning figure only — confirm the final breaker and wire against NEC ampacity tables and local code with a licensed electrician.