12-Inch Pipe Slope Over 25 Feet

A 12-inch sewer or drain line runs at a 0.22% minimum slope. Over a 25-foot run that is 0.06 feet of fall — 0.66 inches (11/16″). If your upstream invert is 100.00 ft, the downstream invert lands at 99.94 ft.

12″ pipe · 25 ft run · 0.22% slope: total fall 0.06 ft (11/16″) · fall per 10 ft: 0.02 ft (0.26″)

Fall table — 12-inch pipe over 25 feet

Distance from startFall so farFall (inches)Invert (if start = 100.00)
25 ft (end)0.06 ft11/16 in99.94 ft

How it is figured

Slope × distance: 0.22% means the pipe drops 0.03 inches for every foot it runs (0.26″ every 10 ft, or 0.02 ft in rod tenths). Over 25 ft: 25 × 0.03″ = 0.66″ = 0.06 ft of fall.

0.22% is the standard minimum for 12-inch pipe — flat enough to keep solids moving without outrunning the water. Run it flatter and the line silts up; much steeper and water can outrun solids on long drops. Always confirm local code — some jurisdictions want more slope on 12-inch lines.

Figure a different run or a custom slope with the free storm drain calculator or the sewer line calculator.

Keep figuring

12″ over 100 ft · 12″ over 75 ft · 12″ over 50 ft · Storm drain calculator · Sewer line calculator · All charts & tables

Common questions

How much fall does a 12-inch pipe need over 25 feet?

At the standard 0.22% minimum slope, a 12-inch pipe falls 0.06 ft (0.66 in.) over 25 ft — 0.26 in. of fall every 10 ft.

What is the minimum slope for 12-inch pipe?

0.22% — that is 0.03 inches of fall per foot of run. It is the widely used minimum for 12-inch sewer and drain pipe; local code can require more.

How do I check the slope with a grade rod?

Grades are read in tenths of a foot. This run drops 0.02 ft every 10 ft, so each 10-foot station should read 0.02 ft lower than the last. String from invert to invert and check the rod at each station against the table above.