4-Inch Pipe Slope Over 25 Feet
A 4-inch sewer or drain line runs at a 2.08% minimum slope. Over a 25-foot run that is 0.52 feet of fall — 6.24 inches (6 1/4″). If your upstream invert is 100.00 ft, the downstream invert lands at 99.48 ft.
Fall table — 4-inch pipe over 25 feet
| Distance from start | Fall so far | Fall (inches) | Invert (if start = 100.00) |
|---|---|---|---|
| 25 ft (end) | 0.52 ft | 6 1/4 in | 99.48 ft |
How it is figured
Slope × distance: 2.08% means the pipe drops 0.25 inches for every foot it runs (2.5″ every 10 ft, or 0.21 ft in rod tenths). Over 25 ft: 25 × 0.25″ = 6.24″ = 0.52 ft of fall.
2.08% is the standard minimum for 4-inch pipe — flat enough to keep solids moving without outrunning the water. Run it flatter and the line silts up; much steeper and water can outrun solids on long drops. Always confirm local code — some jurisdictions want more slope on 4-inch lines.
Figure a different run or a custom slope with the free storm drain calculator or the sewer line calculator.
Keep figuring
4″ over 100 ft · 4″ over 75 ft · 4″ over 50 ft · Storm drain calculator · Sewer line calculator · All charts & tables
Common questions
How much fall does a 4-inch pipe need over 25 feet?
At the standard 2.08% minimum slope, a 4-inch pipe falls 0.52 ft (6.24 in.) over 25 ft — 2.5 in. of fall every 10 ft.
What is the minimum slope for 4-inch pipe?
2.08% — that is 0.25 inches of fall per foot of run. It is the widely used minimum for 4-inch sewer and drain pipe; local code can require more.
How do I check the slope with a grade rod?
Grades are read in tenths of a foot. This run drops 0.21 ft every 10 ft, so each 10-foot station should read 0.21 ft lower than the last. String from invert to invert and check the rod at each station against the table above.