Kipi Calculator PIPE SLOPE CHART by Kipi Calculator
🌐 Español

6-Inch Pipe Slope Over 50 Feet

A 6-inch sewer or drain line runs at a 1.04% minimum slope. Over a 50-foot run that is 0.52 feet of fall — 6.24 inches (6 1/4″). If your upstream invert is 100.00 ft, the downstream invert lands at 99.48 ft.

6″ pipe · 50 ft run · 1.04% slope: total fall 0.52 ft (6 1/4″) · fall per 10 ft: 0.1 ft (1.25″)

Fall table — 6-inch pipe over 50 feet

Distance from startFall so farFall (inches)Invert (if start = 100.00)
25 ft0.26 ft3 1/8 in99.74 ft
50 ft (end)0.52 ft6 1/4 in99.48 ft

How it is figured

Slope × distance: 1.04% means the pipe drops 0.12 inches for every foot it runs (1.25″ every 10 ft, or 0.1 ft in rod tenths). Over 50 ft: 50 × 0.12″ = 6.24″ = 0.52 ft of fall.

1.04% is the standard minimum for 6-inch pipe — flat enough to keep solids moving without outrunning the water. Run it flatter and the line silts up; much steeper and water can outrun solids on long drops. Always confirm local code — some jurisdictions want more slope on 6-inch lines.

Figure a different run or a custom slope with the free storm drain calculator or the sewer line calculator.

Keep figuring

6″ over 100 ft · 6″ over 75 ft · 6″ over 25 ft · Storm drain calculator · Sewer line calculator · All charts & tables

Common questions

How much fall does a 6-inch pipe need over 50 feet?

At the standard 1.04% minimum slope, a 6-inch pipe falls 0.52 ft (6.24 in.) over 50 ft — 1.25 in. of fall every 10 ft.

What is the minimum slope for 6-inch pipe?

1.04% — that is 0.12 inches of fall per foot of run. It is the widely used minimum for 6-inch sewer and drain pipe; local code can require more.

How do I check the slope with a grade rod?

Grades are read in tenths of a foot. This run drops 0.1 ft every 10 ft, so each 10-foot station should read 0.1 ft lower than the last. String from invert to invert and check the rod at each station against the table above.