Header & Beam Calculator
How wide is the opening?
Diagram: what the measurements mean
The rough opening for the door or window — stud to stud.
A standard door is about 3 ft; a wide slider can be 6 ft or more.
What kind of wall?
Load-bearing walls carry weight from above — they need beefier headers.
Pick a wall type to continue.
Your header size
Use this header
–
💡 Pro field tips
🧰 Tools you'll need
Tap to check off as you load up.
Est. project cost (optional)
File this estimate under a job name or PO to track what to order. Leave blank to file under "General".
Copied to clipboard ✓
How the math works
A header is a bridge: the beefed-up beam carrying the wall's load across a window or door opening. The wall above never knows the opening is there — the header picks up the weight and hands it to the king studs on each side. Sizing one means answering three questions: how wide is the opening, how much floor or roof leans on it, and how deep a beam that load demands.
Span: measure the rough opening
The header spans the rough opening — the framed hole, not the window — plus bearing on each side where it rests on the jack studs. A 3-foot window in a 2×4 wall typically gets a 38½-inch rough opening. Longer span, bigger header — no exceptions.
Tributary width: the number everyone misses (background)
A header carries more than the wall above it — it carries a strip of floor or roof on each side, extending halfway to the next support. That strip is the tributary width:
Tributary width = (Joist span on side A ÷ 2) + (Joist span on side B ÷ 2)
If floor joists span 12 feet and rest on this wall from one side, the header carries 6 feet of that floor's width. The name is literal — that strip of floor pays its weight-tribute to your header.
Total load: putting it together (background)
Total load (lbs) = Load (psf) × Tributary width (ft) × Header span (ft)
A 6-foot opening in a bearing wall, joists spanning 12 feet on one side (tributary width 6 ft), floor load 50 psf: 50 × 6 × 6 = 1,800 pounds on that header. That's why headers are doubled or tripled 2× lumber — a single 2×4 would fold like a lawn chair. Important: the load math on this page is background education. This calculator does not compute loads — it sizes your header from the opening width and whether the wall carries load, using its rule-of-thumb table.
Why depth beats width
A beam's stiffness grows with the cube of its depth — double the depth, eight times stiffer — while doubling width only doubles strength. So headers go deeper: a doubled 2×10 vastly outperforms a quadrupled 2×6. Rule of thumb for a single-story bearing wall: one inch of header depth per foot of span — doubled 2×8 to ~4 ft, doubled 2×10 to ~6 ft, doubled 2×12 to ~8 ft. Beyond that, engineered LVL takes over.
Worked example: 6-foot patio door
- Rough opening 6 ft; tributary width 7 ft (joists span 14 ft one side)
- Background load math: 50 × 7 × 6 = 2,100 lbs. The calculator’s rule-of-thumb table (6-ft opening, load-bearing) sizes it as a doubled 2×10
- Waste factor: headers can't be spliced — buy the exact length plus one spare board for a miscut.
When in doubt, go one size up: an oversized header costs a few dollars, an undersized one sags and sticks your doors.
Most Asked Questions
What size header do I need for a 6-foot patio door in a load-bearing wall?
A doubled 2×10. The calculator's rule-of-thumb table sizes a load-bearing opening up to 6 ft as a doubled 2×10, carried on 1 jack stud per side with 1 king stud per side. When in doubt, go one size up: an oversized header costs a few dollars, an undersized one sags and sticks your doors.
What header does a 4-foot window need?
A doubled 2×8 in a load-bearing wall — a doubled 2×6 if the wall carries no load. The table steps with both the opening and the load: load-bearing runs doubled 2×8 to 4 ft, doubled 2×10 to 6 ft, and doubled 2×12 past that, while a non-load-bearing wall runs one size lighter at each step.
How many jack studs and king studs does a header need?
King studs: 1 per side, always. Jack studs: 1 per side up to a 6 ft opening, 2 per side over 6 ft. The header hands the wall's load to the jacks, and the jacks stand next to the kings — that path, header to jack to plate, is what carries the weight around the opening instead of nails alone.
Does this calculator figure the load on the header in pounds?
No — and it says so on the page. The load math in the explanation (load × tributary width × span) is background education. The calculator itself sizes your header from just two inputs — the opening width and whether the wall carries load — using its rule-of-thumb table.
What if my opening is wider than 8 feet?
Treat it as engineered-beam territory. The calculator warns that an opening over 8 ft likely needs an engineered beam such as an LVL, not dimensional lumber, and its own table tops out at a doubled 2×12. Confirm wide spans with local code or an engineer before you frame.
Why do headers get deeper instead of wider?
Depth beats width — a beam's stiffness grows with the cube of its depth. Double the depth and the beam is eight times stiffer; double the width and it only doubles. That is why a doubled 2×10 vastly outperforms a quadrupled 2×6, and why headers stand on edge in the wall.