10-Inch Pipe Slope Over 100 Feet
A 10-inch sewer or drain line runs at a 0.28% minimum slope. Over a 100-foot run that is 0.28 feet of fall — 3.36 inches (3 3/8″). If your upstream invert is 100.00 ft, the downstream invert lands at 99.72 ft.
Fall table — 10-inch pipe over 100 feet
| Distance from start | Fall so far | Fall (inches) | Invert (if start = 100.00) |
|---|---|---|---|
| 25 ft | 0.07 ft | 13/16 in | 99.93 ft |
| 50 ft | 0.14 ft | 1 11/16 in | 99.86 ft |
| 75 ft | 0.21 ft | 2 1/2 in | 99.79 ft |
| 100 ft (end) | 0.28 ft | 3 3/8 in | 99.72 ft |
How it is figured
Slope × distance: 0.28% means the pipe drops 0.03 inches for every foot it runs (0.34″ every 10 ft, or 0.03 ft in rod tenths). Over 100 ft: 100 × 0.03″ = 3.36″ = 0.28 ft of fall.
0.28% is the standard minimum for 10-inch pipe — flat enough to keep solids moving without outrunning the water. Run it flatter and the line silts up; much steeper and water can outrun solids on long drops. Always confirm local code — some jurisdictions want more slope on 10-inch lines.
Figure a different run or a custom slope with the free storm drain calculator or the sewer line calculator.
Keep figuring
10″ over 75 ft · 10″ over 50 ft · 10″ over 25 ft · Storm drain calculator · Sewer line calculator · All charts & tables
Common questions
How much fall does a 10-inch pipe need over 100 feet?
At the standard 0.28% minimum slope, a 10-inch pipe falls 0.28 ft (3.36 in.) over 100 ft — 0.34 in. of fall every 10 ft.
What is the minimum slope for 10-inch pipe?
0.28% — that is 0.03 inches of fall per foot of run. It is the widely used minimum for 10-inch sewer and drain pipe; local code can require more.
How do I check the slope with a grade rod?
Grades are read in tenths of a foot. This run drops 0.03 ft every 10 ft, so each 10-foot station should read 0.03 ft lower than the last. String from invert to invert and check the rod at each station against the table above.