Kipi Calculator PIPE SLOPE CHART by Kipi Calculator
🌐 Español

6-Inch Pipe Slope Over 125 Feet

A 6-inch sewer or drain line runs at a 1.04% minimum slope. Over a 125-foot run that is 1.3 feet of fall — 15.6 inches (15 5/8″). If your upstream invert is 100.00 ft, the downstream invert lands at 98.7 ft.

6″ pipe · 125 ft run · 1.04% slope: total fall 1.3 ft (15 5/8″) · fall per 10 ft: 0.1 ft (1.25″)

Fall table — 6-inch pipe over 125 feet

Distance from startFall so farFall (inches)Invert (if start = 100.00)
25 ft0.26 ft3 1/8 in99.74 ft
50 ft0.52 ft6 1/4 in99.48 ft
75 ft0.78 ft9 3/8 in99.22 ft
100 ft1.04 ft12 1/2 in98.96 ft
125 ft (end)1.3 ft15 5/8 in98.7 ft

How it is figured

Slope × distance: 1.04% means the pipe drops 0.12 inches for every foot it runs (1.25″ every 10 ft, or 0.1 ft in rod tenths). Over 125 ft: 125 × 0.12″ = 15.6″ = 1.3 ft of fall.

1.04% is the standard minimum for 6-inch pipe — flat enough to keep solids moving without outrunning the water. Run it flatter and the line silts up; much steeper and water can outrun solids on long drops. Always confirm local code — some jurisdictions want more slope on 6-inch lines.

Figure a different run or a custom slope with the free storm drain calculator or the sewer line calculator.

Keep figuring

6″ over 75 ft · 6″ over 50 ft · 6″ over 25 ft · Storm drain calculator · Sewer line calculator · All charts & tables

Common questions

How much fall does a 6-inch pipe need over 125 feet?

At the standard 1.04% minimum slope, a 6-inch pipe falls 1.3 ft (15.6 in.) over 125 ft — 1.25 in. of fall every 10 ft.

What is the minimum slope for 6-inch pipe?

1.04% — that is 0.12 inches of fall per foot of run. It is the widely used minimum for 6-inch sewer and drain pipe; local code can require more.

How do I check the slope with a grade rod?

Grades are read in tenths of a foot. This run drops 0.1 ft every 10 ft, so each 10-foot station should read 0.1 ft lower than the last. String from invert to invert and check the rod at each station against the table above.