8-Inch Pipe Slope Over 25 Feet

A 8-inch sewer or drain line runs at a 0.4% minimum slope. Over a 25-foot run that is 0.1 feet of fall — 1.2 inches (1 3/16″). If your upstream invert is 100.00 ft, the downstream invert lands at 99.9 ft.

8″ pipe · 25 ft run · 0.4% slope: total fall 0.1 ft (1 3/16″) · fall per 10 ft: 0.04 ft (0.48″)

Fall table — 8-inch pipe over 25 feet

Distance from startFall so farFall (inches)Invert (if start = 100.00)
25 ft (end)0.1 ft1 3/16 in99.9 ft

How it is figured

Slope × distance: 0.4% means the pipe drops 0.05 inches for every foot it runs (0.48″ every 10 ft, or 0.04 ft in rod tenths). Over 25 ft: 25 × 0.05″ = 1.2″ = 0.1 ft of fall.

0.4% is the standard minimum for 8-inch pipe — flat enough to keep solids moving without outrunning the water. Run it flatter and the line silts up; much steeper and water can outrun solids on long drops. Always confirm local code — some jurisdictions want more slope on 8-inch lines.

Figure a different run or a custom slope with the free storm drain calculator or the sewer line calculator.

Keep figuring

8″ over 100 ft · 8″ over 75 ft · 8″ over 50 ft · Storm drain calculator · Sewer line calculator · All charts & tables

Common questions

How much fall does a 8-inch pipe need over 25 feet?

At the standard 0.4% minimum slope, a 8-inch pipe falls 0.1 ft (1.2 in.) over 25 ft — 0.48 in. of fall every 10 ft.

What is the minimum slope for 8-inch pipe?

0.4% — that is 0.05 inches of fall per foot of run. It is the widely used minimum for 8-inch sewer and drain pipe; local code can require more.

How do I check the slope with a grade rod?

Grades are read in tenths of a foot. This run drops 0.04 ft every 10 ft, so each 10-foot station should read 0.04 ft lower than the last. String from invert to invert and check the rod at each station against the table above.