Free Roof Pitch Calculator
Enter rise and run — get pitch, roof angle, and rafter length instantly.
Common pitches — tap to load:
Add the building span to get the full common-rafter length (ridge to wall).
Your roof pitch
–/12
💡 Pro field tips
- Measure rise and run in the same units — the pitch ratio works in any units.
- Roofs under 4/12 need special underlayment — check shingle manufacturer specs for low-slope installs.
- 12/12 is a 45° roof. Anything steeper and you should be roped off per OSHA fall protection rules.
- Add 12–18 inches of rafter tail for overhang before you buy lumber.
Copied to clipboard ✓
Worked example
You measured a garage roof the simple way — a level and a tape on the slope: 8 inches of rise over 12 inches of run. The building spans 28 ft. Here's everything the calculator pulls out of those numbers:
- Pitch: 8 ÷ 12 × 12 = 8/12 pitch
- Angle: arctan(8 ÷ 12) = 33.7°
- Rafter factor: √(8² + 12²) ÷ 12 = 14.42 ÷ 12 = 1.202 — every foot of horizontal run is 1.202 ft of roof
- Common rafter: half the span is 14 ft × 1.202 = 16.83 ft from ridge to wall — before you add the tail for overhang
- Roof area: each slope is 16.83 ft wide, so on a 40-ft-long building that's about 673 ft² per side — the area you actually order roofing for, not the 560 ft² of footprint
On a real job
- Measure from the attic when you can. A level against the underside of a rafter inside is safer and just as accurate as climbing out on the roof itself — and nobody falls off an attic floor.
- Under 4/12 changes the rules. Low-slope roofs need special underlayment under shingles, and under 2/12 shingles don't belong there at all — that's membrane territory. Know your pitch before you order material.
- Order by slope area, never by footprint. The steeper the roof, the bigger the gap between the floor plan and the roof. At 8/12 the roof is already 20% bigger than the footprint under it.
- Add the tail before you cut or order. The rafter length above ends at the wall. Your overhang — usually 12 to 18 inches — gets added on, or the eaves come up short.
- Steep is a safety category, not a preference. At 12/12 (45°) and beyond, you're in roped-off, fall-protection territory. Price the job like it.
Most Asked Questions
What is roof pitch?
Roof pitch is the steepness of a roof, expressed as inches of vertical rise for every 12 inches of horizontal run. A 6/12 pitch rises 6 inches for every 12 inches it runs.
How do I measure rise and run on a real roof?
Measure 12 inches of level run and read the rise straight up from it. In the attic, hold a level against the underside of a rafter, mark 12 inches along it, and measure vertically from that point up to the rafter — that vertical number is your rise per 12. Enter any rise and run in the same units above; the calculator does the rest.
What angle is a 6/12 pitch?
26.6°. For reference, the common pitches run: 4/12 = 18.4°, 6/12 = 26.6°, 8/12 = 33.7°, 12/12 = 45°. The angle is the arctangent of rise divided by run — this calculator works it out from whatever rise and run you enter.
How long a rafter do I need for an 8/12 roof on a 28-foot span?
About 16.83 feet for the common rafter. An 8/12 slope runs 14.42 inches of rafter for every 12 inches of run — a slope factor of 1.202. Half the 28 ft span is 14 ft of run, and 14 × 1.202 = 16.83 ft. That is wall to ridge: add your overhang tail before you cut.
Does pitch change the size of my roof?
Yes — the slope area is bigger than the footprint, by the slope factor. At 8/12 the factor is 1.202, so one roof side covering 560 sq ft of floor plan (40 ft long × 14 ft of run) is really about 673 sq ft of roof. Order material by slope area, never by footprint.
What does this calculator leave out?
Everything beyond the common rafter. It gives pitch, angle and common-rafter length for one slope. It does not figure overhang tails, ridge board thickness, the birdsmouth cut, or hip and valley rafters — and it doesn't count roofing material. Confirm the final cut list on site.
Estimates for planning only — confirm final quantities with your supplier and follow local building code.